Basic Certified Service Technician Training

Click here to see the current class schedule and to register.

Download the Training Pricing Guide

Basic Certified Service Technician Training

Course Number: ST301

Duration: Two days, 8:30 a.m. – 5:00 p.m.

Certification: Dated Certificate of Completion, valid for 2 years

Overview

This course is designed for new technicians with little or no previous gas detection or RAE Systems experience or those who would like a refresher course covering our legacy products. This two-day course covers the basics of servicing gas detection instruments and covers RAE Systems’ established products: MultiRAE Plus, MiniRAE 2000 and ppbRAE Plus, QRAE and QRAE Plus, and VRAE. Attendees who complete this class and pass the examination at the end will be able to:

  • Service and maintain the MultiRAE Plus, MiniRAE 2000 and ppbRAE Plus, QRAE and QRAE Plus, and VRAE, including:
    • Configure, program and test the monitor
    • Download datalogged data, upload configurations and firmware
    • Field verify and calibrate the monitor
    • Conduct standard field diagnostic tests
    • Troubleshoot pump and sensor problems
    • Maintain PID lamps and sensors
    • Replace sensors, lamps and pumps

Agenda Day 1

Time
Subject
8:30 a.m. - 11:30 a.m. Servicing the MultiRAE Plus
  • An overview of Diagnostic Mode and practice of standard field tests. Replacement of sensor, lamp and pump. Maintenance.
11:30 a.m. - 12:30 p.m. Lunch
12:30 p.m. - 4:00 p.m. Servicing the MultiRAE Plus, cont'd
  • An overview of Diagnostic Mode and practice of standard field tests. Replacement of sensor, lamp and pump. Maintenance.
4:00 p.m. - 5:00 p.m. Servicing the QRAE Plus
  • An overview of Diagnostic Mode and practice of standard field tests. Replacement of sensor, lamp and pump. Maintenance.

Agenda Day 2

Time
Subject
8:30 a.m. - 10:00 a.m. Inside the EntryRAE
  • An overview of Diagnostic Mode and replacement of sensors. Maintenance.
10:00 a.m. - 11:30 a.m. Servicing the VRAE
  • An overview of Diagnostic Mode and practice of standard field tests. Replacement of sensors and pump. Maintenance.
11:30 a.m. - 12:30 p.m. Lunch
12:30 p.m. - 3:00 p.m. Servicing the MiniRAE 2000/ppbRAE Plus
  • An overview of Diagnostic Mode and practice of standard field tests. Replacement of sensor, lamp and pump. Maintenance.
3:00 p.m. - 4:30 p.m. Servicing the UltraRAE
  • An overview of Diagnostic Mode and practice of standard field tests. Replacement of sensor, lamp and pump. Maintenance.
4:30 p.m. - 5:00 p.m. Quiz